Shopping Cart
View Cart
Checkout
# of Item(s): 0
Total: $0.00
Hanna HI93114 Turbidity and Chlorine Measurement in One Meter
 

Hanna HI93114 Turbidity and Chlorine Measurement in One Meter

Price: $676.00
Quantity:
Detailed Description
Specifications

Description

With the hand-held HI 93114, three important parameters in water quality analysis are at your fingertips. Free and total chlorine measurements and US EPA compliant turbidity measurements are performed quickly and reliably with this lab-grade microprocessor-based field instrument. HI 93114 is particularly useful for potable water measurements and municipalities.

The rugged HI 93114 will log data for up to 25 measurements along with time and date information for retrieval at a later date. This instrument also offers Good Laboratory Practice (GLP) features which allow the user to verify the calibration status of the meter.

With HI 93114 measurements can be performed using either concentration or relative absorbance of the sample depending on the requirements of the application.

HI 93114 can be calibrated using the factory preprogrammed calibration points or can be custom calibrated when in colorimetric mode.

This rugged instrument has been engineered to offer all the sophistication and reliability of bench top laboratory instrumentation in the size of a hand-held meter.

Specifications

Range Turbidity 0.00 to 9.99 FTU;
10.0 to 50.0 FTU
Range Free Chlorine 0.00 to 2.50 mg/L
Range Total Chlorine 0.00 to 3.50 mg/L
Resolution Turbidity 0.01 FTU (0.00 to 9.99 FTU);
0.1 FTU (10.0 to 50.0 FTU)
Resolution Chlorine 0.01 mg/L
Accuracy Turbidity ±0.5 FTU or ±5% of reading (whichever is greater)
Accuracy Chlorine ±0.03 mg/L or ±3% of reading (whichever is greater)
Calibration   2 points, selectable between 0.00 - 50.0 FTU
(0.00 and 20.0 FTU recommended)
Light Source   Green LED
Light Life   Life of the instrument
Light Detection   2 Silicon Photocells
Battery Type / Life   4 x 1.5V AA / approx. 60 hours of continuous use or 1000 measurements;
automatic shut-off after 10, 20, 30, 40, 50 or 60 minutes
(User-Selectable)
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
Weight   510 g (1.1 lb.)

Accessories

To View or Buy Any Accessory, Search For Item By Name (Click and Paste).

Solutions
HI 93102-0 AMCO-AEPA-1 Calibration Solution at 0 NTU
HI 93102-20 AMCO-AEPA-1 Calibration Solution at 20 NTU
Accessories
HI 731318 Tissue for Wiping Cuvets
HI 731321 Glass Cuvet for HI 937xx & HI 832xx Series Meters
HI 731327 Maintenance Kit for HI 93102 & HI 93114
Reagents & Standards
HI 93701-01 Chlorine, free, DPD Method (100 Tests)
HI 93701-03 Chlorine, free, DPD Method (300 Tests)
HI 93711-01 Chlorine, Total, DPD Method (100 Tests)
HI 93711-03 Chlorine, Total, DPD Method (300 Tests)

Order Info

HI 93114 is supplied with glass cuvet, batteries and instructions.