Description
HI 112 and HI 113 are designed for those users that require the highest level of precision over the entire pH range. These meters are ideal for the most challenging applications where the sample pH may vary greatly.
Depending on the level of precision required for each application, the user can select the pH resolution as 0.01 or 0.001.
These meters maintain a high degree of precision over the entire measurement range; maximized when the automatic 5 point calibration is employed. Choose the most suitable buffers for your system from among 7 memorized values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45).
If the memorized buffer values are not the most ideal for your application, HI 112 and HI 113 will allow you to manually set 2 custom pH values for calibration.
These instruments also feature an extended temperature range (from -9.9 to 120°C), GLP functions, manual or automatic temperature compensation and an RS232 serial port for PC connection. All data can be downloaded and manipulated with the HI 92000 application software.
Specifications
| Range | pH | 2.00 to 16.00 pH; -2.000 to 16.000 pH |
| Range | mV | ±999.9 mV; ±2000 mV |
| Range | Temperature | -9.9 to 120.0°C |
| Resolution | pH | 0.01 pH; 0.001 pH |
| Resolution | mV | 0.1 mV; 1 mV |
| Resolution | Temperature | 0.1°C |
| Accuracy | pH | ±0.01 pH; ±0.002 pH |
| Accuracy | mV | ±0.5 mV; ±1 mV |
| Accuracy | Temperature | ±0.4°C |
| Relative mV Offset Range | | ±2000 mV |
| pH Calibration | | automatic, up to 5 points with 7 memorized values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers |
| Temperature Compensation | | Automatic (with HI 7669/2W probe) or manual from -9.9 to 120°C |
| pH Electrode | | HI 1131B, glass-body, double junction, refillable, BNC connector, 1 m (3.3') cable (included) |
| Temperature Probe | | HI 7669/2W with 1 m (3.3') cable (included) |
| Input Impedance | | 1012 Ohm |
| PC Connection | | RS232 opto-isolated serial port |
| Power Supply | | 12 Vdc adapter (included) |
| Environment | | 0 to 50°C (32 to 122°F); RH max 95% |
| Dimensions | | 240 x 182 x 74 mm (9.4 x 7.2 x 2.9") |
| Weight | | 1.1 kg (2.4 lb.) |
Accessories
To View or Buy Any Accessory, Search For Item By Name (Click and Paste).
| Electrodes |
| HI 11X1 Series | Laboratory Combination pH and ORP Electrodes |
| HI 7669/2W | Temperature Probe |
| Solutions |
| HI 7004L | 4.01 pH Buffer Solution 1 x 500 mL bottle |
| HI 7007L | 7.01 pH Buffer Solution 1 x 500 mL bottle |
| HI 7010L | 10.01 pH Buffer Solution 1 x 500 mL bottle |
| HI 77400P | Combination pH Buffer Kit 4.01 & 7.01 pH |
| HI 70300L | Electrode Storage Solution 1 x 500 mL bottle |
| Accessories |
| HI 710005 | Voltage adapter from 115V to 12 Vdc (USA plug) |
| HI 710006 | Voltage adapter from 230V to 12 Vdc (European plug) |
| HI 92000 | Windows® Compatible Software for Logging Instruments, Photometers and Turbidity Meters |
| HI 920010 | Cable for PC Connection, 9 to 9-pin |
| HI 76404 | Electrode Holder |
Order Info
HI 113 is supplied with HI 1131B pH electrode, HI 7669/2W temperature probe, pH 4 and pH 7 buffer sachets (20 mL each), electrode refilling solution, electrode holder, 12 Vdc power adapter and instructions.
Manufacturer: N/A
SKU: HI113