Shopping Cart
View Cart
Checkout
# of Item(s): 0
Total: $0.00
Hanna HI9828 Multiparameter Water Quality Portable Meter
 

Hanna HI9828 Multiparameter Water Quality Portable Meter

Price: $2,025.00
Quantity:
Detailed Description
Specifications

Description:

The HI 9828 Multiparameter Portable Meter is a comprehensive analytical instrument, capable of measuring up to 13 critical water quality parameters (6 measured and 7 calculated), including pH, EC/TDS, ORP, DO, atmospheric pressure, and temperature. Some of the most advanced capabilities available are incorporated into this portable meter. Designed for intuitive operation, the menu-driven navigation is user-friendly and logical. A backlit 128 x 64 pixels graphic LCD, that automatically sizes the digits, allows full configuration of each measured parameter, displays on-screen graphing and has options for units and language selections, provides high-quality resolution and sophistication that is unsurpassed in its class.

Engineered with smart features such as auto recognition of pH/ORP probe, auto-ranging adjustments for EC/TDS readings, and measurement check - to eliminate erroneous readings - and more, our design actually simplifies operations and handling. There is virtually no learning curve to getting into this meter and quickly mastering it's capabilities. Each parameter is fully supported by the on-screen contextual HELP function, which is active during measurement and calibration modes. For field applications, Hanna's Quick Calibration allows the user to standardize pH, conductivity and dissolved oxygen, all with one solution! While in calibration mode, the meter will also assess and verify probe functionality. For monitoring and recording data, HI 9828 can be equipped with the optional T.I.S. - Tag Identification System: iButton©s with unique ID numbers. Installed at any sampling site, these tags will record and match specific location information with logging data. Comprehensive GLP features, such as last calibration date and status information, calibration time-out, and date and time tags associated with sample measurements, ensure consistency and accountability. The LOGGER function memorizes data from each connected sensors and log-on-demand & automatic logging can record up to 60,000 data samples. All data is downloadable to a PC via USB connectivity.

HI 9828 is designed for demanding outdoor environments. The meter is impact resistant and waterproof to IP67 standards (30 minutes immersion under 1 m of water), and the multi-sensor probe, HI 769828, with an IP68 rating, can be left underwater for an extended period of time. This intelligent probe contains a built-in microprocessor with amplifiers, interprets the high impedance signals from each sensor and sends the converted data to the meter. Consequently, common tolerance issues associated with high impedance signals, such as limiting cable length, and noise interferences are eliminated. The probe maintains reliable communication with the meter, and the user is warned of any problems, such as a broken cable line.

Specifications:

Range

pH

0.00 to 14.00 pH

Resolution

pH

0.01 pH

Accuracy

pH

±0.02 pH

Range

mV

±600.0 mV

Resolution

mV

0.1 mV

Accuracy

mV

±0.5 mV

Range

mV

±2000.0 mV

Resolution

mV

0.1 mV

Accuracy

mV

±1.0 mV

Range

DO

0.0 to 500.0%; 0.00 to 50.00 mg/L

Resolution

DO

0.1% / 0.01 mg/L

Accuracy

DO

0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 mg/L: ±1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ±3% of reading

Range

EC

0.000 to 200.000 mS/cm (actual EC up to 400 mS/cm)

Resolution

EC

Manual: 1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm Automatic: 1 μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm ; 0.1 mS/cm from 100.0 to 400.0 mS/cm Automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm

Accuracy

EC

±1% of reading or ±1 μS/cm whichever is greater

Range

Resistivity

0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm

Resolution

Resistivity

Dependent on resistivity reading

Range

TDS

0 to 400000 mg/L or ppm (the maximum value depends on the TDS factor)

Resolution

TDS

Manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt) Auto-range scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt) Auto-range g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)

Accuracy

TDS

±1% of reading or ±1 mg/L

Range

Salinity

0.00 to 70.00 PSU (extended Practical Salinity Scale)

Resolution

Salinity

0.01 PSU

Accuracy

Salinity

±2% of reading or 0.01 PSU whichever is greater

Range

Seawater Specific Gravity

0.0 to 50.0 σt, σ0, σ15

Resolution

Seawater Specific Gravity

0.1 σt, σ0, σ15

Accuracy

Seawater Specific Gravity

±1 σt, σ0, σ15

Range

Atm. Pressure

450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa

Resolution

Atm. Pressure

0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

Accuracy

Atm. Pressure

±3 mmHg within ±15°C from the temperature during calibration

Range

Temperature

-5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K

Resolution

Temperature

0.01°C; 0.01°F; 0.01K

Accuracy

Temperature

±0.15°C; ±0.27°F; ±0.15K

Calibration

pH

Automatic 1, 2, or 3 points with 5 memorized standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer

Calibration

mV

Automatic at 1 custom point

Calibration

Conductivity, Salinity

Automatic 1 point with 6 memorized standards (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point

Calibration

DO

Automatic 1 or 2 points at 0, 100% or 1 custom point

Calibration

Resistivity, TDS

Based on conductivity or salinity calibration

Calibration

Atm. Pressure

Automatic at 1 custom point

Calibration

Temperature

Automatic at 1 custom point

Temperature Compensation

 

Automatic from -5 to 55°C (23 to 131°F)

Logging Memory

 

Up to 60000 samples with 13 measurements each

Logging Interval

 

1 second to 3 hours

PC Connection

 

USB (with HI 92000 software)

Waterproof Protection

 

Meter IP67, Probe IP68

Environment

 

0 to 50°C (32 to 122°F); RH 100%

Power Supply

 

(4) 1.5V alkaline C cells (approx. 150 hours of continuous use without backlight)/ (4) 1.2V rechargeable C cells (approx. 70 hours of continuous use without backlight)

Dimensions

 

Meter: 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”); Probe: 270 x 46 mm DIA (10.6 x 1.8” DIA)

Weight

 

Meter: 750g (26.5 oz.); Probe: 750g (26.5 oz.)

Accessories:

Solutions

Click To View or Buy

Quick Calibration Solution 500mL

Click To View or Buy

Quick Calibration Solution 1G

Accessories

 

Click To View or Buy

 Hanna HI710045 Ac Power Cord

Click To View or Buy

 Hanna HI710046 12V Portable Automobile Power Cord

Click To View or Buy

Tag Identification System (T.I.S.)

Click To View or Buy

Electrolyte Solution for Galvanic Probes
1 x 30mL bottle

Click To View or Buy

USB Interface Cable

Click to View or Buy

Probe Maintenance Kit

Click To View or Buy

Calibration Beaker

Click To View or Buy

Flow Cell

Click To View or Buy

DO/Temperature Sensor

Click To View or Buy

EC Sensor

Click to View or Buy

pH Sensor

Click To View or Buy

pH/ORP Sensor

Order Info:
HI 9828 is supplied with HI 769828 multisensor probe (pH/ORP, EC, DO, temperaure), HI 9828-25 quick calibration standard solution (500 mL), probe maintenance kit, rechargeable C size Ni-MH batteries (4), power adapter & cable, car 12V accessory outlet adapter, HI 7698281 USB interface cable, HI 92828 Windows® compatible software and instruction manual in a rugged carrying case.
Downloads:
Manual: (Download)
Literature: (Download)

Return to Catalog